
Choose your machine
DPF cleaning machine prices and comparison
Compare METClean DPF cleaning machines by filter size, drying, testing and site requirements. The table shows each current price with its VAT basis.
What does a DPF cleaning machine cost?
Check the prices in the table below. Installation and training vary by model and site. Ask for a written quote that includes the work required for your workshop or van.
Which suits your work?
You clean HGV, bus, plant or agricultural filters.
The XL Multi+ has space for large-format filters and automatic programmes for supported components.
METClean XL Multi+You want a touchscreen, pneumatic clamping and a record of every job.
The S adds touchscreen control, pneumatic clamping, heated drying and a pre-test with a printed record and emailed inspection report.
METClean SYou clean car and van DPFs and want a simpler, lower-cost start.
The E runs its automatic wash from analogue controls, with a compressed-air cold purge.
METClean EYou run, or are building, a mobile DPF service.
The V is a compact cabinet designed around a van, for collection, clean and return work.
METClean VYou want an off-vehicle service without a full cabinet.
The DPF Lite is a bench machine that runs a controlled cycle while you work.
METClean DPF Lite
Side by side
On a phone, scroll the table sideways; the machine names and the first column stay in place. Prices come from the MET shop with their VAT basis.
| Feature | METClean XL Multi+ | METClean S | METClean E | METClean V | METClean DPF Lite |
|---|---|---|---|---|---|
![]() | ![]() | ![]() | ![]() | ![]() | |
| Use | |||||
| Best for | Heavy-duty, fleet, plant and multi-service work | Car and LCV workshops wanting touchscreen control, clamping and reporting | Entry to cabinet cleaning, car and LCV | Compact cabinet for a van, variable water flow, cold dry. | Lower-cost bench machine with a controlled cycle. |
| Applications | Car, Van, HGV and Plant | Car and Van | Car and Van | Car and Van | On request |
| Component types | DPF, GPF, OPF, CAT, SCR, DOC, EGR, Intercooler and Radiator | DPF, GPF, OPF, CAT, SCR, DOC, EGR, Intercooler and Radiator | DPF, GPF, OPF, CAT, SCR, DOC, EGR, Intercooler and Radiator | DPF, GPF, OPF, CAT, SCR, DOC, EGR, Intercooler and Radiator | DPF |
| Size and capacity | |||||
| External dimensions | 2,100 × 980 × 2,100 mm (W × D × H) | 1,640 × 800 × 2,100 mm (W × D × H) | 1,320 × 800 × 2,060 mm (W × D × H) | 903 × 1,178 × 1,145 mm (W × D × H) | 1,390 × 710 × 1,090 mm (W × D × H) |
| Working space | 1.87 m³ | 0.82 m³ | 0.82 m³ | 0.94 m³ | On request |
| Weight, empty | 500 kg | 280 kg | 240 kg | 150 kg | 50 kg |
| Weight, operating | 700 kg | 430 kg | 390 kg | 230 kg | 80 kg |
| Tank capacity | 200 litres | 150 litres | 150 litres | 80 litres | 25 litres |
| Tank and water service | Drain the tank and clear ash every 60 cleans, sooner if needed | Drain the tank and clear ash every 60 cleans, sooner if needed | Drain the tank and clear ash every 60 cleans, sooner if needed | Drain the tank and clear ash every 60 cleans, sooner if needed | Expected cleans per fill: 2 |
| Utilities | |||||
| Electrical supply | 240 V single phase on a 32 A supply with RCD; runs from a 13 A plug without water heating or hot air | 240 V single phase on a 32 A supply with RCD; runs from a 13 A plug without water heating or hot air | 240 V single phase on a 32 A supply with RCD; runs from a 13 A plug without water heating | 220–250 V single phase, 50 Hz; draws 6 A (1.44 kW) from a standard 13 A supply | 220–240 V single phase, standard 3-pin plug, under 4 A |
| Protective device | 32 A Type C breaker on 6 mm² cable, with RCD | 32 A Type C breaker on 6 mm² cable, with RCD | 32 A Type C breaker on 6 mm² cable, with RCD | 13 A | Standard 13 A plug; RCBO in the machine |
| Air inlet pressure | 5 bar | 5 bar | 5 bar | 5–8 bar | 5 bar |
| Process | |||||
| Control | PLC touchscreen; automatic programmes for every component type | Touchscreen; automatic programme for DPF and GPF | Automatic cycle; analogue switches and timer | Automatic cycle; analogue controls, variable water flow | Digital timers; automatic programme with manual water and air buttons |
| Loading | Clamped in cabinet | Pneumatic clamping in cabinet | Manual strap restraint | Manual strap restraint | Manual strap clamp |
| Soft start | Yes, adjustable | Yes, adjustable | Yes | Yes | Yes |
| Pressure test | Yes, before cleaning; an after reading is for reference only | Yes, before cleaning; an after reading is for reference only | No, optional retrofit kit | No, optional retrofit kit | No |
| Printout | Yes, company, operator, customer, filter serial number | Yes, company, operator, customer, filter serial number | No | No | No |
| Emailed pre-clean inspection report | Yes, from the machine, before cleaning; printing still available | Yes, from the machine, before cleaning; printing still available | No | No | No |
| Drying | Hot dry and cold purge | Hot dry and cold purge | Cold air purge | Cold air purge | On request |
| Filtration | |||||
| Filtration stages | Tank filter, sediment bag filter and four stainless micron filters | Six-filter system: tank filter, sediment bag filter and four stainless micron filters | Two-filter system: tank filter and sediment bag filter | Pickup filter and one sock filter | On request |
| Finest filtration | 25 micron | 25 micron | 50 micron | 50 micron | On request |
| Filtration pressure | 1.5–3 bar | 1.5–3 bar | 1.5–3 bar | 1.5–3 bar | On request |
| Washes between bag filter changes | 30 | 30 | 30 | 30 | On request |
| Washes between mesh filter cleans | 15 | 15 | On request | On request | On request |
| Ownership | |||||
| Installation | MET delivers and positions the XL Multi+, connects it to the supplies you have ready, then fills it and runs a test clean. Included where your site meets the minimum requirements. | MET delivers and positions the S, connects it to the supplies you have ready, then fills it and runs a test clean. Included where your site meets the minimum requirements. | Usually installed by the buyer, with remote onboarding from MET; MET can fit it at extra cost, quoted per job. | Agreed per order: fitted in your van by MET at extra cost, or by your own installer. | No installation needed: it runs from a standard plug and your workshop air. |
| Training | On site at installation, for whoever is there on the day, with a signed handover sheet. Free remote refresher training for new staff. | On site at installation, for whoever is there on the day, with a signed handover sheet. Free remote refresher training for new staff. | Instructional videos and remote onboarding; on-site training at extra cost, quoted per job. Free remote refresher training for new staff. | On site when MET fits the van; at MET if you fit it yourself. Free remote refresher training for new staff. | Remote onboarding from MET. Free remote refresher training for new staff. |
| Warranty | 12 months from installation, or from delivery if you install it yourself. If a fault can't be fixed with our help, MET arranges the repair, with an engineer visit or an authorised repair on site. The written warranty sets out the cover in and outside Great Britain. | 12 months from installation, or from delivery if you install it yourself. If a fault can't be fixed with our help, MET arranges the repair, with an engineer visit or an authorised repair on site. The written warranty sets out the cover in and outside Great Britain. | 12 months from installation, or from delivery if you install it yourself. If a fault can't be fixed with our help, MET arranges the repair, with an engineer visit or an authorised repair on site. The written warranty sets out the cover in and outside Great Britain. | 12 months from installation, or from delivery if you install it yourself. Repairs are carried out at the MET factory, with carriage agreed case by case. The written warranty sets out the cover in and outside Great Britain. | 12 months from installation, or from delivery if you install it yourself. If a fault can't be fixed with our help, MET arranges the repair, with an engineer visit or an authorised repair on site. The written warranty sets out the cover in and outside Great Britain. |
| Price | £24,995 + VAT | £15,995 + VAT | £8,995 + VAT | £14,995 + VAT | £4,700 + VAT |
Plan the cost of running the service
A useful buying comparison includes the work around the clean as well as the machine itself. Build your estimate from your own job mix, labour and local charges.
Site preparation and installation
Check the space, access, electrical supply, compressed air, water and waste arrangements for your chosen model. Confirm who prepares the site and what is included in the installation.
Labour and filter handling
Allow for diagnosis, removal and refitting where offered, inspection, connection, handling and final checks. An automatic cleaning cycle does not remove these workshop tasks.
Water, energy and consumables
Allow for electricity, compressed air, water, filters and any cleaning product required by the approved procedure. Usage depends on the machine and the condition of the filters.
Maintenance and waste
Include routine maintenance and an appropriate route for used water, sediment and spent filters. Follow the operating and maintenance instructions for your machine.
Training and support
Compare the training included with the model and any additional installation or training you need. Read the support and written warranty information before ordering.
Use the calculator to test your own expected volume and charges. Its example figures are a starting point for a business case, not a forecast of your earnings.
Can I compare running costs before buying?
Yes. Allow for labour, filter handling, consumables and waste, then use the calculator to test your expected volume and price per clean.
Estimate revenue, costs and payback




